辐射防护 ›› 2024, Vol. 44 ›› Issue (S1): 126-131.

• 核与辐射事故应急准备与对策 • 上一篇    

基于电阻释光检测方法的辐射应急剂量评估特性

马蕾, 纪云龙, 王易龙, 陈淑年, 宁静, 郭俊旺   

  1. 军事科学院 军事医学研究院辐射医学研究所,北京 100850
  • 收稿日期:2023-11-23 出版日期:2024-11-20 发布日期:2024-12-26
  • 通讯作者: 郭俊旺。E-mail:guojunwang.thaa.@vip.163.com
  • 作者简介:马蕾(1990—),女,2017年毕业于军事医学科学院辐射防护及环境保护专业,工学硕士。E-mail:malei943053@sina.com

Characteristics of emergency radiation dosimetry based on TL/OSL measurement with resistances

MA Lei, JI Yunlong, WANG Yilong, CHEN Shunian, NING Jing, GUO Junwang   

  1. Institute of Radiation Medicine, Academy of Military Medical Science, Beijing 100850
  • Received:2023-11-23 Online:2024-11-20 Published:2024-12-26

摘要: 针对核应急医学救援中伤员外照射剂量快速评估的需求,利用热释光(TL)和光释光(OSL)检测方法,对辐照后的表面贴片电阻器件进行了检测,观察了其用于辐射应急剂量评估的特性。实验结果表明,(1)检测效率方面,单个样品检测时间在100 s可以获得有效的辐射诱发信号;(2)信号稳定性方面,对于10 Gy照射的电阻进行热释光测量相对标准差为4.3%,光释光测量的相对标准差为3.4%;(3)剂量线性方面,在0~100 Gy范围内,热释光测量的线性相关系数为0.987 0,光释光测量的线性相关系数为0.997 5,线性度在较宽剂量范围内较好;(4)检测限,OSL方法约为0.12 Gy,TL方法约为0.02 Gy,满足急性放射病分类需求;(5)时间衰退特性,对于辐照后电阻样品的热释光和光释光检测信号,均呈现出先快后慢的衰减特点,可近似视为指数型衰减,进行剂量重建时需考虑时间衰减校正,但是在辐照发生7~10 d后,仍然具有作为剂量重建的灵敏度。

关键词: 电阻, 热释光, 光释光, 辐射, 剂量评估

Abstract: For the purpose of rapid external radiation dose assessment in nuclear emergency medical rescue, thermoluminescence (TL) and optically stimulated luminescence (OSL) methods were used to detect the irradiated SMD resistance and their characteristics for emergency radiation dose assessment were studied. Experimental results indicated that: (1) Detection efficiency: radiation induced effective signal could be obtained with a detection time of 100 s; (2) Signal stability: the relative standard error of TL measurement for 10 Gy irradiated resistance was 4.3%, and the relative Standard error of OSL measurement was 3.4%; (3) Dose response linearity: in the range of 0-100 Gy, the linear correlation coefficient of TL measurement was 0.987 0, and the linear correlation coefficient of OSL measurement was 0.997 5. (4) The detection limit was 0.12 Gy for OSL measurement and 0.02 Gy for TL measurement, indicating that this method could meet the needs of acute radiation disease classification; (5) Time decay characteristics: the TL and OSL detection signals decayed fast in the first days and then slowly, which could be regarded as exponential type decay. This result showed that the time decay calibration should be considered in dose reconstruction. However, it still reserved sufficient sensitivity for dose reconstruction after 7-10 days.

Key words: resistance, thermoluminescence, optically stimulated luminescence, radiation, dosmetry

中图分类号: 

  • TL73