  • Received:2023-09-06 Published:2025-01-06

摘要: 瞬时事故一般指瞬时放射性释放或极短时间内的放射性释放场景,采用传统连续点源弥散模型开展主控室可居留性后果评价并不合适,本文参考了瞬时烟团弥散的基本模型,结合核电厂的实际设计特点,得到了适用于瞬时事故情况下的主控室可居留性评价大气弥散模型,并基于某核电厂典型的瞬时事故工况开展模型应用,同时与传统连续点源弥散模型进行对比。结果表明:瞬时烟团模型更能表征瞬时释放事故的特点,且主控室的可居留性评价的大气弥散结果与事故初始烟团体积大小紧密关联,根据本文针对烟团初始体积的影响分析可知,释放源项总量相同的情况下,瞬时事故烟团体积越大,对于主控室可居留性后果影响越低。

关键词: 瞬时事故, 主控室, 大气弥散模型, 可居留性评价, 连续点源

Abstract: Instantaneous accidents generally refer to instantaneous radioactive releases or extremely short time radioactive release scenarios. It is not appropriate to adopt the traditional point source dispersion model for continuous release to evaluate the habitability consequence of Main Control Room (MCR). This paper refers to the basic model of instantaneous plume release model and considers the actual design characteristics of nuclear power plants to form an atmospheric dispersion model for evaluating the habitability of MCR under instantaneous accident conditions. The model was utilized based on a typical instantaneous accident. The comparison results with traditional point source dispersion model show that the model formed in this paper can better characterize the release characteristics of such accidents, and the atmospheric dispersion results used for evaluating the habitability of MCR are closely related to the volume of instantaneous accident plume. Additional analysis conducted in this paper indicates that under the same released source terms, the larger the volume of released plume, the lower the radioactive impact on the MCR.

Key words: instantaneous accident, main control room, atmospheric dispersion mode, habitability assessment, point source

中图分类号: 

  • TL73