RADIATION PROTECTION ›› 2015, Vol. 35 ›› Issue (3): 158-162.

Previous Articles     Next Articles

Experimental study on lowly concentrated CH3I measurement for iodine absorber efficiency evaluation

Zhang Jirong1, Li Yongguo1, Wang Haiwei2, Wang Tun3, Han Lihong1, Zhang Xueping1, Zhang Qun1, Zhou Sheng2, Liu Xianli1, Wu Bo1   

  1. 1. China Institute for Radiation Protection, Tanyuan 030006;
    2. China Nuclear Power Operation and Management Company Limited, Zhejiang Haiyan 314300;
    3. China Nuclear Power Engineering Co. Ltd., Guangdong Shenzhen 518124
  • Received:2014-05-22 Online:2015-05-20 Published:2024-10-21

Abstract: To overcome the defect of being radioactive operation, CH1273I was tentatively used in iodine absorber performance evaluation. The difficulty for the research is about the analytical method for CH1273I. This paper recommends that CH1273I is analyzed by GC. The results show that the limit deterministic concentration is low, the injected CH1273I is only 2% relative to the designed adsorbed capacity. The imported biggest amount of stable CH1273I will not greatly damage the performance of iodine absorbers to absorb radioactive CH1313I in nuclear facilities. It is feasible when CH1273I is absorbed by chromatograph-grade ethanol, then analyzed by GC.

Key words: nuclear ventilation system, iodine absorber, gas-chromatograph analysis, methyl iodide

CLC Number: 

  • TL941+.21