Abstract: Background count rate deducted LaBr3:Ce scintillator was used to detect 16N. Results show a better detection efficiency and energy resolution of it, enabling full energy area detection thusly. An alert level of leakage was added that decreases the steam generator's threshold of leakage alarm. The function of count rate and energy spectrum integration is supplemented after alarming to display the real time leakage progress. Leakage simulation is achieved at different levels through slow and fast motion play of screen recording.

Key words: background deducted LaBr3:Ce scintillator, embedded α source and γ included source, count rate and integral count, alert level of leakage, leakage simulation, slow and fast motion play of the screen recording