RADIATION PROTECTION ›› 2014, Vol. 34 ›› Issue (4): 206-213.

Previous Articles     Next Articles

Improvement and its Validation to the Flue Gas Cleaning System in Low-level Waste Incinerator

Zheng Bowen, Xu Wei, Yang Lili, Wang Peiyi, Li Xiaohai, Yang Liguo, Zhang Xiaobin, Wang Xujin, Li Chuanlian, Jia Chengming, Chu Haoran   

  1. China Institute for Radiation Protection, Taiyuan 030006
  • Received:2013-09-30 Online:2014-07-20 Published:2025-01-10

Abstract: Problems including material corrosion and redundant waste water have been found in ZRF15 radioactive waste incinerator after several years' operation. Improvements were made in the design of ZRF25 in terms of the technical process and mechanism of the flue gas cleaning system. The initial temperature of flue gas in quench was decreased. A pre-filter was installed before HEPA. The waste water treatment system was constructed. The material of equipment was improved. Results of cold and hot commissioning demonstrate the cleaning effect is desirable, the operation safety is improved, the equipment had better corrosion resistance, and the secondary waste is decreased.

Key words: radioactive waste, incineration, flue gas cleaning, waste treatment

CLC Number: 

  • TL941+.32