辐射防护 ›› 2017, Vol. 37 ›› Issue (3): 174-179.

• 辐射防护监测 • 上一篇    下一篇

基于CR39固体核径迹探测器的低能中子剂量测量方法初步研究

曹磊1, 邓君2, 兰长林3, 宋延超2, 丁晓文1, 马驰1, 郭泽钦1, 郑昀1, 邱羽桐1   

  1. 1.北京市化工职业病防治院,北京 100093;
    2.中国疾病预防控制中心辐射防护与核安全医学所,北京 100088;
    3.兰州大学核科学技术学院,兰州 730000
  • 收稿日期:2015-12-31 出版日期:2017-05-20 发布日期:2021-11-11
  • 作者简介:曹磊(1975—),1996年毕业于兰州大学自动化仪表专业,2005年毕业于兰州大学粒子物理与原子核物理专业,获硕士学位,副研究员。E-mail:caolnirp@163.com
  • 基金资助:
    科研院所技术开发研究专项基金(2012EG150137);北京市职业病防治领域高层次专业技术人才培养项目(2014742603767J008)。

Study on dosimetric method of low energy neutron with CR39 solid state nuclear track detector

Cao Lei1, Deng Jun2, Lan Changlin3, Song Yanchao2, Ding Xiaowen1, Ma Chi1, Guo Zeqin1, Zheng Yun1, Qiu Yutong1   

  1. 1. Beijing Chemical Occupational Disease Prevention and Treatment Center,Beijing 100093;
    2. National Institute for Radiological Protection, CDC, Beijing 100088;
    3. Lanzhou University,Lanzhou 730000
  • Received:2015-12-31 Online:2017-05-20 Published:2021-11-11

摘要: 本文给出了一种采用固体核径迹探测器测量低能(0.5 eV以下能量)中子的双片径迹计数方法,利用蒙特卡罗模拟和实验,统计分析了低能中子引起的探测器单位面积径迹密度。结果显示,采用双片径迹计数方法,实现了CR39对于低能中子的响应,可以对低能中子引起的个人剂量进行估算。应用在中子职业个人剂量监测时,有效甄别了背景径迹的影响,因而降低了测量误差,对减小中子个人剂量监测的测量不确定度也是一个可行的方法。

关键词: CR39固体核径迹探测器, 低能中子, 蒙特卡罗模拟, 双片径迹计数

Abstract: A dual-track counting method and a detector structure for measuring low energy neutrons (energy below 0.5 eV) with a solid state nuclear track detector are described. The detector track density per unit area induced by low energy neutron was analyzed by both Monte Carlo simulation and field experiments. The results showed that the dual-track counting method achieved the response of CR39 to low energy neutrons, suggesting that individual dose induced by low energy neutron could be estimated with this method. The energy response range of CR39 was extended so that low energy neutrons with fluence of less than 104 could be measured. The dual-track counting method can effectively discriminate the background track for monitoring of personal neutron dose, thus the measurement uncertainty is reduced.

Key words: CR39 solid state nuclear track detector, low energy neutron, Monte Carlo simulation, dual-track counting