辐射防护 ›› 2017, Vol. 37 ›› Issue (3): 161-168.

• 剂量学基础 • 上一篇    下一篇

基于MCNP对γ射线吸收剂量累积因子的计算与研究

李华1,2, 赵原1, 刘立业1, 肖运实1, 李君利2   

  1. 1.中国辐射防护研究院保健物理研究所剂量学研究室,太原 030006;
    2.清华大学工程物理系,粒子技术与辐射成像教育部重点实验室,高能辐射成像重点学科实验室,北京 100084
  • 收稿日期:2016-08-09 出版日期:2017-05-20 发布日期:2021-11-11
  • 通讯作者: 刘立业。E-mail:liuliye@cirp.org.cn
  • 作者简介:李华(1989—),男,2011年毕业于清华大学工程物理系,助理研究员。E-mail:lihua_7559@126.com
  • 基金资助:
    国家自然科学基金资助项目(项目编号:11305146、11275174)。

Research on gamma ray buildup factor for energy absorption based on MCNP

Li Hua1,2, Zhao Yuan1, Liu Liye1, Xiao Yunshi1, Li Junli2   

  1. 1. China Institute for Radiation Protection,Taiyuan 030006;
    2. Department of Engineering Physics, Tsinghua University, Key Laboratory of Particle and Radiation Imaging, Ministry of Education, Key Laboratory of High Energy Radiation Imaging Fundamental Science, Beijing 100084
  • Received:2016-08-09 Online:2017-05-20 Published:2021-11-11

摘要: 使用蒙特卡罗程序MCNP计算了常用材料下的吸收剂量累积因子,计算时采用了较新的截面数据库MCPLIB04及介质材料的衰减参数数据库,并考虑了轫致辐射和相干散射等物理过程,同时将计算结果与相关文献给出的数据进行了比较,分析了造成差异的主要原因。结果表明:利用MCNP计算出的低Z材料的吸收剂量累积因子值在入射光子的中能区部分,平均比文献给出的数据偏小,在高能区部分平均比其偏大;而利用MCNP计算出的高Z材料的吸收剂量累积因子则普遍比文献给出的数据偏大。本文工作可为更新目前使用的较为陈旧的累积因子数据库提供参考。

关键词: 累积因子, MCNP, 吸收剂量, 点核积分

Abstract: Energy absorption buildup factors of common materials were calculated using the Monte Carlo simulation code MCNP. In the calculations, the newer cross section library (MCPLIB04) and mass energy coefficients of common materials have been used with consideration of the bremsstrahlung and correlative scatter. The results were compared with the reference data and the differences were analyzed. It showed that, for the low-Z materials, the values of buildup factors calculated by MCNP were averagely smaller than the reference data for the intermediate γ energies, whilst the calculated values were averagely bigger than the reference data for the high γ energies. For high-Z materials, the calculated results of buildup factors were generally bigger than the reference data. This work could provide updated data for the old buildup factors.

Key words: buildup factor, MCNP, absorbed dose, point-kernel integral