辐射防护 ›› 2026, Vol. 46 ›› Issue (1): 76-82.

• 核设施运行辐射防护 • 上一篇    下一篇

核电厂堆芯测量系统的非计划照射风险分析和管控

伦振明   

  1. 中广核(深圳)运营技术与辐射监测有限公司,广东 深圳 518124
  • 收稿日期:2025-06-08 出版日期:2026-01-20 发布日期:2026-02-06
  • 作者简介:伦振明(1980—),男,2007年毕业于南华大学核电运行专业,高级工程师。E-mail:lunzm@163.com

Unplanned external radiation exposure risks and control measures of the in-core measurement system in nuclear power plants

LUN Zhenming   

  1. China General Engineering Co., Ltd., Guangdong Shenzhen 518124
  • Received:2025-06-08 Online:2026-01-20 Published:2026-02-06

摘要: 核电厂在运行期间需测量堆芯的中子通量分布,由于中子通量测量相关部件会进入燃料组件发生裂变反应和被活化,从而有着极高且复杂的人员照射风险,从1997年至2024年,在行业中已陆续发生数起与中子通量测量相关的严重的非计划照射事件。以M310堆型作为基础,根据中子通量测量的工作过程,展开详细的风险分析,结合行业中非计划照射事件的失效原因,在优化核电厂通用管控措施的基础上,进一步应用纵深防御原则,提出了“通过物理屏障和联锁来弥补潜在的人为差错”的方法,并在M310堆型首次应用。所述的风险分析和管控措施可供国内基于M310演变的CPR1000、CNP600、CNP1000等堆型机组参考,以防止事件发生,保护工作人员安全。

关键词: 核电厂, 中子通量测量, 通量探测器, 指套管, 非计划照射风险, 管控措施

Abstract: During the operation of a nuclear power plant, it is necessary to measure the neutron flux distribution in the reactor core. As components related to neutron flux measurement enter fuel assemblies, where fission reactions occur and the components themselves become activated, there exists an extremely high and complex risk of unplanned radiation exposure to personnel. From 1997 to 2024, several serious unplanned radiation exposure incidents related to neutron flux measurement have occurred in the industry. Taking the M310 reactor type as the reference, this paper conducts a detailed risk analysis based on the operational process of neutron flux measurement. By combining the failure causes of unplanned radiation exposure incidents in the industry, and on the basis of optimizing general control and prevention measures for nuclear power plants, this paper further applies the principle of defense-in-depth and proposes an innovative method of “using physical barriers and interlocks to compensate for potential human errors”. This method has been applied for the first time in the M310 reactor type. The risk analysis and control measures described in this paper can serve as a reference for domestic reactor types evolved from the M310, such as CPR1000, CNP600, and CNP1000, to prevent the recurrence of similar incidents and protect personnel safety.

Key words: nuclear power plant, neutron flux measurement, flux detector, thimble, risk of unplanned radiation exposure, control and prevention measures, recommendations

中图分类号: 

  • TL38