辐射防护 ›› 2025, Vol. 45 ›› Issue (5): 474-481.

• 辐射防护监测 • 上一篇    下一篇

AP1000蒸汽发生器排污管道γ在线监测装置设计及探测效率分析

王一霖1, 乔有龙1, 余小东1, 刘维理2, 夏三强3, 苏昌远3   

  1. 1.山东核电有限公司,山东 海阳 265100;
    2.国电投核能有限公司,山东 烟台 264000;
    3.中国辐射防护研究院,太原 030006
  • 收稿日期:2025-04-02 出版日期:2025-09-20 发布日期:2026-01-14
  • 作者简介:王一霖(1990—),男,2012年毕业于东北电力大学核工程与核技术专业,工程师。E-mail:623493070@qq.com

Design and detection efficiency analysis on online γ radiation monitoring device for AP1000 steam generator blowdown pipeline

WANG Yilin1, QIAO Youlong1, YU Xiaodong1, LIU Weili2, XIA Sanqiang3, SU Changyuan3   

  1. 1. Shandong Nuclear Power Co., Ltd., Shandong Haiyang 265100;
    2. State Power Investment Corporation Nuclear Energy Co., Ltd., Shandong Yantai 264000;
    3. China Institute for Radiation Protection, Taiyuan 030006
  • Received:2025-04-02 Online:2025-09-20 Published:2026-01-14

摘要: 为了确保AP1000机组外供蒸汽中放射性物质符合相关标准要求,对蒸汽发生器排污管道的γ放射性进行实时在线监测。γ在线监测装置由4台NaI(Tl)γ谱仪、就地辐射处理单元和铅屏蔽支架组成。NaI(Tl)γ谱仪采用4个大体积NaI(Tl)晶体包围管道,实现了高探测效率和低本底计数率。模拟结果表明监测装置的探测效率受γ射线能量影响较小。通过配制含有137Cs不同活度浓度的管道,对监测装置进行刻度,得到探测效率为7.96×10-2,在95%置信度、15 s测量时间下最小可探测活度浓度为2.53×104 Bq/m3,监测装置精密度为2.86%,准确度优于±9%,满足测量需求。

关键词: 低γ放射性测量, 最小可探测活度浓度, 管旁在线监测, AP1000

Abstract: In order to ensure that radioactive substances in the external steam supply of AP1000 unit meet the relevant standard requirements, real-time online monitoring of the γ radioactivity in the steam generator blowdown pipeline is carried out. The online γ radiation monitoring device consists of four NaI (Tl) γ spectrometers, an on-site radiation processing unit, and a lead shielding bracket. The simulation results indicate that the detection efficiency of the monitoring device is less affected by the energy of γ rays. By preparing pipelines with different activity concentrations of 137Cs and calibrating the monitoring device, a detection efficiency of 7.96×10-2 was obtained. At a 95% confidence level and a measurement time of 15 seconds, the minimum detectable activity concentration was 2.53×104 Bq/m3. The precision of the monitoring device was 2.86%, and the accuracy was better than ±9%, meeting the measurement requirements.

Key words: low γ radiation measurement, minimum detectable activity concentration, online monitoring at the management site, AP1000

中图分类号: 

  • TL75+1