Detection of Fuel Assembly Damage at Ningde Nuclear Power Plant by Using Sipping Device

Zhan Xiaocong, Liu Heng, Liu Hui, Gao Huibin1, Jiang Yafeng2, Wu Huaqiang, Pan Erquang, Bai Zhaotao, Yu Liangzhong, Chen Zhanggui, Liu Nin, Cai Xiangyu   

  1. FuJian Ningde Nuclear Power Co., Ltd., Fujian Fuding, 355200;
    1. Yangjiang Nuclear Power Co., Ltd., Guangdong Yangjiang, 529500;
    2. Suzhou Nuclear Power Research Institute, Suzhou, 215000
  • Received:2014-08-29 Online:2014-10-20 Published:2025-02-24

Abstract: The optimization and application of a domestic online sipping device are described in this paper. By optimizing and resetting key parameters, analyzing the threshold counting rate data in the form of chart, using 241Am radioactive source to help locate the 81 keV position, we optimized the device state and sought out the failed fuel elements successfully during refueling outages.