Design and detection efficiency analysis on online γ radiation monitoring device for AP1000 steam generator blowdown pipeline

WANG Yilin1, QIAO Youlong1, YU Xiaodong1, LIU Weili2, XIA Sanqiang3, SU Changyuan3   

  1. 1. Shandong Nuclear Power Co., Ltd., Shandong Haiyang 265100;
    2. State Power Investment Corporation Nuclear Energy Co., Ltd., Shandong Yantai 264000;
    3. China Institute for Radiation Protection, Taiyuan 030006
  • Received:2025-04-02 Online:2025-09-20 Published:2026-01-14

Abstract: In order to ensure that radioactive substances in the external steam supply of AP1000 unit meet the relevant standard requirements, real-time online monitoring of the γ radioactivity in the steam generator blowdown pipeline is carried out. The online γ radiation monitoring device consists of four NaI (Tl) γ spectrometers, an on-site radiation processing unit, and a lead shielding bracket. The simulation results indicate that the detection efficiency of the monitoring device is less affected by the energy of γ rays. By preparing pipelines with different activity concentrations of 137Cs and calibrating the monitoring device, a detection efficiency of 7.96×10-2 was obtained. At a 95% confidence level and a measurement time of 15 seconds, the minimum detectable activity concentration was 2.53×104 Bq/m3. The precision of the monitoring device was 2.86%, and the accuracy was better than ±9%, meeting the measurement requirements.

Key words: low γ radiation measurement, minimum detectable activity concentration, online monitoring at the management site, AP1000

CLC Number: 

  • TL75+1