RADIATION PROTECTION ›› 2019, Vol. 39 ›› Issue (1): 40-44.

Previous Articles     Next Articles

Study on limit condition for operation in technical specifications ofthe radioactive specific activity in coolant of nuclear power plant

FU Yaru, PAN Nan, MEI Qiliang, LI Huaibin, MAO Lanfang   

  1. Shanghai Nuclear Engineering Research & Design Institute, Shanghai 200233
  • Received:2018-08-24 Online:2019-01-20 Published:2019-11-08

Abstract: The background and meaning of the limits formulation were revealed based on the study of the specific activity limits of primary coolant in Westinghouse standard specifications. This is helpful for the in-depth understanding and follow-up implementation of the relevant operation provisions. Through the comparison between AP1000 power plant specifications and Westinghouse standard specifications, it is found that the total specific radioactivity limit in AP1000 power plant specifications is replaced by the dose equivalent of 133Xe specific activity limit in AP1000 power plant specifications. The dose equivalent of 131I and 133Xe specific activity limit are calculated based on the design basis of 0.25% fuel cladding defect. The source terms used in shielding design, waste treatment system design and accident radioactive consequence analysis are consistent. Finally, combined with the requirements of domestic regulations and standards, some suggestions were given on adjusting the iodine spike specific activity limits and dose equivalent of 131I and 133Xe specific activity limit according to the source terms of 0.25% fuel cladding defect.

Key words: technical specifications, iodine, specific activity, limit condition for operation, AP1000

CLC Number: 

  • TL353+.5