RADIATION PROTECTION ›› 2019, Vol. 39 ›› Issue (1): 27-32.

Previous Articles     Next Articles

Comparative study on the radon ventilation in hydropowerunderground engineering based on calculationof ventilation volume and radon exhalation rate

CHEN Gang, HU Penghua, LI Xianjie, REN Jianjun, KANG Jianqiao   

  1. Beijing Research Institute of Chemical Engineering and Metallurgy, Beijing 101101
  • Received:2018-06-27 Online:2019-01-20 Published:2019-11-08

Abstract: Taking a hydropower underground engineering project as an example, the air volume of radon reduction had been calculated according to the ventilation volume and radon emanation quantity. The result showed that the air flow could be reviewed according to the radon emanation quantity when the increment of underground radon concentration was greater than 200 Bq/(m3·h). Otherwise, the air flow could be reviewed on the basis of the ventilation volume. This method provided technical supports for the design of underground hydropower engineering.

Key words: hydropower underground engineering, radon emanation quantity, dehumidification and hypothermia, ventilation rate