RADIATION PROTECTION ›› 2018, Vol. 38 ›› Issue (6): 480-485.

Previous Articles     Next Articles

Evaluation of protection performance against weak penetration by some personal protective equipment

WEI Yingjing1, ZHAO Pengfei2, NI Wei2, WEI Xiaofeng1, LIi Hua1, LIU Liye1   

  1. 1. China Institute for Radiation Protection, Taiyuan 030006;
    2. CNNC Nuclear Power Operations Management Co., Ltd., Zhejiang Haiyan 314300
  • Received:2018-04-09 Online:2018-11-20 Published:2020-07-21

Abstract: In order to identify the protection effect of personal protective equipment on different energy β rays, the protection effects of personal protective equipment on H·′(0.07) and H·′(3) under various combinations of different energy β radiation fields were measured in 85Kr and 90Sr-90Y standard β radiation fields. During the outage of the nuclear power plant,the weak penetrating radiation protection effect of personal protective equipment on some positions was measured. The results show that the protective effect of personal protective equipment on field radiation is different because of the different β/γ value of the surface of the equipment being measured. Especially in the places with strong γ rays,the protective effect of personal protective equipment on H·′(0.07) and H·′(3) is generally poor, while the protective effect of protective glasses against weak penetration radiation is rather significant. It is suggested that workers should wear protective glasses in high energy β radiation field to reduce the dose of lens. Due to the poor protective effect of personal protective equipment on high-energy β radiation,the monitoring methods and protective measures for workers working in high-energy β radiation sites are given.

Key words: β ray, attenuation ratio, H·′(0.07), H·′(3)

CLC Number: 

  • TL75+2