RADIATION PROTECTION ›› 2018, Vol. 38 ›› Issue (6): 457-464.

Previous Articles     Next Articles

Investigation on weak penetration radiation of valves in Qinshan phase II nuclear power plant

WANG Chuan1, WEI Yingjing2, NI Wei1, LIU Liye2, CHEN Chenxiang1, CAO Qinjian2   

  1. 1. CNNC Nuclear Power Operations Management Co., Ltd., Zhejiang Haiyan 314300;
    2. China Institute for Radiation Protection, Taiyuan 030006
  • Received:2018-08-06 Online:2018-11-20 Published:2020-07-21

Abstract: The radiation sources and weak penetration radiation of the main valves in four systems of the RCP, RRA, RCV and PTR are monitored during the eight outages in Qinshan phase II nuclear power plant. 110mAg is the main radioactive nuclide measured in valve deposition of RCV system. 58Co,60Co,95Nb,95Zr,51Cr and other radionuclides are deposited in valves of RCP, RRA and PTR systems. The associated β ray energy is mainly in the range of 500 keV. The*(10),H·′(0.07) and H·′(3) are measured for four types of valves. The value of H·′(3) /H·*(10) is about 1.24, and the value of H·′(0.07)/H·*(10) is about 14. According to the measurement results, monitoring of eye lens and skin dose for maitenance workers in some key valves are suggested.

Key words: nuclear power plant, valve, radiological, weak penetration radiation

CLC Number: 

  • TL75+1