RADIATION PROTECTION ›› 2017, Vol. 37 ›› Issue (4): 322-326.

Previous Articles     Next Articles

Discussion on accident source term and emergency planning zone of ACP100

Luo Feng, Li Guoqing   

  1. Institute for Standardization of Nuclear Industry, Beijing 100091
  • Received:2016-08-08 Online:2017-07-20 Published:2021-11-11

Abstract: The influence of unique design of the ACP100 on the accident source term is analyzed. The applicability of alternative source term (AST), mechanistic source term (MST) and mixed accident source term are compared. Suggestions on determination of mixed source term and emergency planning zone of the ACP100 are given.

Key words: ACP 100, accident source term, emergency planning zone

CLC Number: 

  • TL75