RADIATION PROTECTION ›› 2016, Vol. 36 ›› Issue (5): 272-278.

Previous Articles     Next Articles

Investigation of shielding system of radioactive water filters in nuclear power plant

Xue Feng, Zhao Yanpeng, Chen Bin, Lv Jun   

  1. Liaoning Hongyanhe Nuclear Power Co. Ltd., Liaoning Dalian, 116001
  • Received:2015-12-29 Online:2016-09-20 Published:2021-11-15

Abstract: Combining with the characteristics of the 11th filter of the Reactor Boron and Water Makeup System (REA011FI), the design and practice of installing fixed boron shielding equipment were discussed. The application of such equipment in LHNP had been proved practicable that the dose rate in the room which REA001FI located had decreased almost 80% and the collective dose of a single unit had reduced approximately 13.44 man·mSv/a, and it is a good practice in application of radiation protection ALARA principle.

Key words: radiation, filter, shield equipment, collective dose

CLC Number: 