RADIATION PROTECTION ›› 2015, Vol. 35 ›› Issue (2): 104-111.

Previous Articles     Next Articles

Design and construction of a multi-pass test stand for filtration performance evaluation of nuclear-grade water filter element

Shen Dapeng, Qiu Dangui, Shi Yingxia, Liu Qun, Hou Jianrong, Kong Haixia, Wang Ruiyun, Liu Xianli   

  1. China Institute for Radiation Protection, Taiyuan 030006
  • Received:2013-03-20 Online:2015-03-20 Published:2024-10-21

Abstract: The design and the selection of main equipment and instruments of the multi-pass test stand in evaluating filtration performance of a nuclear-grade water filter element were discribed. Some conclusions were obtained through performance tests: the maximum water flux of 4.0 m3/h for the standard filter element, and the maximum fracture strength of 0.4 MPa both meets the test requirements; particle distribution of the test system is uniform and stable, which basically meet the deviation of within ±15% between the given particle size number of each sampling interval and the average value; for the contamination impouring test, the weight contamination degree of each sample and the average value is controlled within ±5%, and the deviation between the average value and theoretical value is less than ±10%, and the deviation between the average impouring flow rate and the predetermined impouring flow rate is within ≤5%.

Key words: nuclear grade water filter, filter element, filtration performance, multi-pass method

CLC Number: 

  • TQ051.8+5