RADIATION PROTECTION ›› 2014, Vol. 34 ›› Issue (3): 162-167.
Previous Articles Next Articles
Wei Yingjing1, Meng Yanjun1, Ke Haipeng2, Zhao Pengfei2, Gu Weigang1, Zhang Qingli1
Received:
Online:
Published:
Abstract: According to the national standard GB/T 4835—2008 and the verification regulation JJG 393—2003 for radiation protection instrumentation, 40 radiation protection γ monitors of different types were tested using X and γ reference radiation devices of the radiation metrology station of China Institute for Radiation Protection (CIRP). Judging by the test results of these monitors in terms of repeatability, relative intrinsic error, energy dependence of response, angle dependence of response, and alarm sound, it is known that about 50% of these monitors fails to meet the standards.
Key words: γ radiation monitor, repeatability, relative intrinsic error, energy dependence of response, angle dependence of response
CLC Number:
Wei Yingjing, Meng Yanjun, Ke Haipeng, Zhao Pengfei, Gu Weigang, Zhang Qingli. Performance Assessment of Gamma-ray Monitors for Radiation Protection Monitoring in China[J].RADIATION PROTECTION, 2014, 34(3): 162-167.