RADIATION PROTECTION BULLETIN ›› 2018, Vol. 38 ›› Issue (3): 29-32.

Previous Articles     Next Articles

Personal Dose Monitoring of Staff during the Construction and Commissioning of China Spallation Neutron Source from 2014 to 2017

Ye Rong1, 2, Wang Qingbin1, 2, Wu Qingbiao1, 2, Wang Huaibao1, 2, Wang Yufei1, 2   

  1. 1. China Spallation Neutron Source, Institute of High Energy Physics, CAS, Dongguan, Guangdong, 523803;
    2. Dongguan Institute of Neutron Science, Dongguan, Guangdong, 523803
  • Received:2018-03-02 Online:2018-07-20 Published:2020-07-29

Abstract: The situation of personal dose monitoring for workers involved in the construction and commissioning of China spallation neutron source from 2014 to 2017 is presented. The routine monitoring method, with the OSL 4 component badge-type personal dosimeter employed, was used. Theaverage effective doses obtained are 0.11, 0.11, 0.15, 0.15 mSv/a respectively, with the corresponding maximum of 0.9, 0.27, 0.62, 0.65 mSv/a. It showsthat the annual effective dose per capita is much smaller than the facility's management target (10 mSv/a).