Abstract: By combining a 1030W total carbon analyzer and a 3180 liquid scintillation counter, a method for measuring 14C in NPP liquid effluents was established. It was achieved by using the totalcarbon analyzer to have the carbon in sample acidized and oxidized to carbon dioxide, which was then absorbed with a sodium hydroxide solution, and succeeded byliquid scintillation measurement. The method can effectively eliminate interference from other radionuclides, and can accurately determine 14C activity in the sample. The results show that its overall average recovery was 96.91%,detection limit was 2.07 Bq/L, and, the precision (relative standard deviation)and accuracy (relative error) of measurement results was less than ±5% respectively.

Key words: NPP, Liquid effluence, 14C