辐射防护通讯 ›› 2025, Vol. 45 ›› Issue (2): 6-14.

• 研究通报 • 上一篇    下一篇

核电厂核辅助系统管道的超声换能器阵列清洗效果仿真研究

李雪菲1, 白云慷2, 李建宇1, 詹杰1, 黄新明3, 陈志远3, 杨俊武3, 单陈瑜1, 张臣2   

  1. 1.中广核研究院有限公司,广东 深圳 518028;
    2.南京航空航天大学机电学院,江苏 南京 210016;
    3.大亚湾核电运营管理有限责任公司,广东 深圳 518124
  • 收稿日期:2024-05-30 出版日期:2025-04-20 发布日期:2025-04-29
  • 作者简介:李雪菲(1996—),女,2021年毕业于吉林大学材料学专业,硕士,长期从事辐射防护相关材料研发工作,工程师。E-mail:lixuefei@cgnpc.com.cn

Simulation study on the cleaning effect of ultrasonic transducer array for auxiliary system pipeline in nuclear power plant

LI Xuefei1, BAI Yunkang2, LI Jianyu1, ZHAN Jie1, HUANG Xinming3, CHEN Zhiyuan3, YANG Junwu3, SHAN Chenyu1, ZHANG Chen2   

  1. 1. China Nuclear Power Technology Research Institute, Guangdong Shenzhen 518028;
    2. College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics,Jiangsu Nanjing 210016;
    3. Daya Bay Nuclear Power Operation and ManagementCo. Ltd., Guangdong Shenzhen 518124
  • Received:2024-05-30 Online:2025-04-20 Published:2025-04-29

摘要: 本文提出一种“V字形”超声换能器阵列,用于清洗核电厂核辅助系统管道内壁的沉积物,以避免传统的超声清洗中多个换能器的“一字形”阵列的驻波效应而导致管道另一侧清洗不完全的现象。通过Comsol软件进行声-流-固多物理场耦合仿真,研究了“V字形”阵列在管道中的清洗效果。仿真结果表明,当超声激励电压幅值为400 V,“V字形”阵列中的三个换能器分别以0°、45°、90°相位激励时,管道内水场分布均匀,最大声压达157 kPa,超过空化阈值,能产生空化现象,同时,换能器阵列对管道内壁污垢层的作用力表现出内周期性变化。基于该结果,提出了电压幅值400 V、相位分别为0°、45°和90°的“V字形”阵列作为清洗工艺的参考参数,为核电厂管道去污提供了有效的技术方案。

关键词: 核管道, 超声清洗, 换能器阵列, Comsol仿真

Abstract: This paper proposes a "V-shaped" ultrasonic transducer array for cleaning the inner walls of pipelines in the auxiliary systems of nuclear power plants, aiming to avoid the incomplete cleaning on the opposite side of the pipelines caused by the standing wave effect associated with the traditional "linear" arrangement of multiple transducers in ultrasonic cleaning. Multi-physics coupling simulations were performed by using Comsol to investigate the cleaning effect of the "V-shaped" array in the pipe. The simulation results show that when the ultrasonic excitation voltage is set to 400 V, and the three transducers in the "V-shaped" array are excited with phases of 0°, 45°, and 90°, respectively, the water field in the pipe is more evenly distributed. The maximum sound pressure reaches 157 kPa, exceeding the cavitation threshold, which induces cavitation. Additionally, the force exerted by the transducer array on the pipe′s inner wall deposits varies periodically. Based on these results, the voltage of 400 V and the excitation phases of 0°, 45°, and 90° are proposed as reference parameters for the cleaning process, providing an effective reference for the decontamination process of pipelines in nuclear power plant.

Key words: nuclear pipeline, ultrasonic cleaning, transducer array, Comsol simulation