Radiation protection monitoring and control under the condition of fuel defects for PWR

YANG Junwu1, ZHOU Liangfa2, GAO Xing1, LUN Zhengming3, LIU Qiang1, ZHOU Zhihui1, XU Qiang1, LI Wei1   

  1. 1.Daya Bay Nuclear Power Operations and Management Co. Ltd., Guangdong Shenzhen 518124;
    2. CGN Nuclear Power Operations Management Co. Ltd., Guangdong Shenzhen 518124;
    3. CGN Radiation Monitoring Technology Co. Guangdong Shenzhen 518124
  • Received:2019-04-03 Online:2019-09-15 Published:2019-10-14

Abstract: Monitoring and control plan for gaseous fission products, as wel as radiation protection measures during power operation and refueling outage when fuel defect occurred in PWR, are introduced in this paper. The overall implementation of the plan and measures during sixth outage of Lingao unit 2 (L206) is presented. The monitoring data of air pollution and α contamination are analyzed and evaluated.

Key words: nuclear power plant, fuel defect, air contamination, protection, monitoring