[1] Clairand I, Trompier F, Bottollier-Depois JF, et al. Exvivo ESR measurements associated with Monte Carlo calculations for accident dosimetry: application to the 2001 Georgian accident[J]. Radiation Protection Dosimetry, 2006, 119(1-4): 500-505. [2] Huet C, Trompier F, Clairand I, et al. Physical dosimetric reconstruction of a radiological accident at Fleurus (Belgium) on 11 March 2006[J]. Radiation Measurements, 2008, 43(2): 845-848. [3] Wieser A. Review of reconstruction of radiation incident air kerma by measurement of absorbed dose in tooth enamel with EPR[J]. Radiation Protection Dosimetry, 2012, 149(1): 71-78. [4] Levue P, Desmet C, Dos Santos-Goncalvez AM, et al. Influence of free radicals signal from dental resins on the radio-induced signal in teeth in EPR retrospective dosimetry[J]. PlOS ONE, 2013, 8(5): e62225. [5] Fattibene P, Callens F. EPR dosimetry with tooth enamel: a review[J]. Applied Radiation and Isotopes, 2010, 68(11): 2 033- 2 116. [6] Vral A, Fenech M, Thierens H. The micronucleus assay as a biological dosimeter of in vivo ionising radiation exposure[J]. Mutagenesis, 2011, 26(1): 11-17. [7] Belyaev IY. Radiation-induced DNA repair foci: spatio-temporal aspects of formation, application for assessment of radiosensitivity and biological dosimetry[J]. Mutation Research/Reviews in Mutation Research, 2010, 704(1): 132-141. [8] Clairand I, Huet C, Trompier F, et al. Physical dosimetric reconstruction of a radiological accident due to gammagraphy equipment that occurred in Dakar and Abidjan in summer 2006[J]. Radiation Measurements, 2008, 43(2): 698-703. [9] Symons MCR, Chandra H, Wyatt JL. Electron paramagnetic resonance spectra of irradiated finger-nails: a possible measure of accidental exposure[J]. Radiation Protection Dosimetry, 1995, 58(1): 11-15. [10] Romanyukha A, Trompier F, LeBlanc B, et al. EPR dosimetry in chemically treated fingernails[J]. Radiation Measurements, 2007, 42(6): 1 110-1 113. [11] Trompier F, Queinnec F, Bey E, et al. EPR retrospective dosimetry with fingernails: report on first application cases[J]. Health Physics, 2014, 106(6): 798-805. [12] Trompier F, Romanyukha A, Reyes R, et al. State of the art in nail dosimetry: free radicals identification and reaction mechanisms[J]. Radiation and Environmental Biophysics, 2014,1-13. [13] DiCarlo AL, Maher C, Hick JL, et al. Radiation injury after a nuclear detonation: medical consequences and the need for scarce resources allocation[J]. Disaster Medicine and Public Health Preparedness, 2011, 5(S1): S32-S44. [14] Trompier F, Kornak L, Calas C, et al. Protocol for emergency EPR dosimetry in fingernails[J]. Radiation Measurements, 2007, 42(6): 1 085-1 088. [15] Reyes RA, Romanyukha A, Trompier F, et al. Electron paramagnetic resonance in human fingernails: the sponge model implication[J]. Radiation and Environmental Biophysics, 2008, 47(4): 515-526. [16] Reyes RA, Romanyukha A, Olsen C, et al. Electron paramagnetic resonance in irradiated fingernails: variability of dose dependence and possibilities of initial dose assessment[J]. Radiation and Environmental Biophysics, 2009, 48(3): 295-310. [17] Chandra H, Symons MCR. Sulphur radicals formed by cutting α-keratin[J]. Nature, 1987, 328(6133): 833-834. [18] Romanyukha A, Reyes RA, Trompier F, et al. Fingernail dosimetry: current status and perspectives[J]. Health Physics, 2010, 98(2): 296-300. [19] Swartz HM, Iwasaki A, Walczak T, et al. In vivo EPR dosimetry to quantify exposures to clinically significant doses of ionising radiation[J]. Radiation Protection Dosimetry, 2006, 120(1-4): 163-170. [20] Trompier F, Romanyukha A, Kornak L, et al. Electron paramagnetic resonance radiation dosimetry in fingernails[J]. Radiation Measurements, 2009, 44(1): 6-10. [21] Reyes RA, Trompier F, Romanyukha A. Study of the stability of EPR signals after irradiation of fingernail samples[J]. Health Physics, 2012, 103(2): 175-180. [22] Engin B, Aydas C, Demirtas H. Study of the thermoluminescence dosimetric properties of window glass[J]. Radiation Effects & Defects in Solids: Incorporating Plasma Science & Plasma Technology, 2010, 165(1): 54-64. [23] Kharita MH, Yousef S, Bakr S. The use of commercial glass as a potential gamma accidental dosimeter through the absorption spectra[J]. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2012, 278: 50-57. [24] Bartolotta A, Brai M, Caputo V, et al. Thermoluminescence response of sodalime glass irradiated with photon and electron beams in the 1—20 Gy range[J]. Radiation Measurements, 2011, 46(9): 975-977. [25] Liu ZM, Wu D, Liu XK, et al. Reconstruction of through-and-through cheek defects with folded free anterolateral thigh flaps[J]. Journal of Oral and Maxillofacial Surgery, 2013, 71(5): 960-964. [26] Matsuda N, Kumagai A, Ohtsuru A, et al. Assessment of internal exposure doses in Fukushima by a whole body counter within one month after the nuclear power plant accident[J]. Radiation Research, 2013, 179(6): 663-668. [27] Morita N, Miura M, Yoshida M, et al. Spatiotemporal characteristics of internal radiation exposure in evacuees and first responders after the radiological accident in Fukushima[J]. Radiation Research, 2013, 180(3): 299-306. |