RADIATION PROTECTION ›› 2014, Vol. 34 ›› Issue (2): 86-90.

Previous Articles     Next Articles

Influences of Improvement to Steam Generator’s Secondary Aerosol Deposition Model on BP Release Category

Huang Gaofeng   

  1. Shanghai Nuclear Engineering Research and Design Institute,Shanghai 200233
  • Received:2012-12-13 Online:2014-03-20 Published:2025-01-03

Abstract: Large frequency containment bypass (BP) accidents have big contributions to radiological consequences of a severe accident. MAAP4.0.4 is used to calculate source term of AP1000 BP release category, but it is incapable of accurate simulation for aerosol deposition in the complicated structure of secondary steam generator. With the basis of overseas experiments, aerosol deposition model is developed in this work, then the source code of MAAP4.0.4 is changed. Reassessment of BP release category is done, which indicates that, old model is conservative.

Key words: secondary aerosol deposition, model improvement, BP release category

CLC Number: 

  • TL364