摘要: 介绍了我国首座自主研发的示范快堆核电站区域辐射监测系统的初步设计,并与中国实验快堆及典型压水堆核电站区域辐射监测系统设计进行了对比,为施工设计提供理论依据。
关键词: 快堆, 辐射监测, 场所
Abstract: In this paper, the preliminary designof the area radiation monitoring system for fisrt Chinese-designed fast reactorNPP (CFR600) has been completed. A comparison of radiation monitoring systems is made between the China Experimental Fast Reactor (CEFR) and a typical PWR NPP,thus providing a theoretical basis for the next stage of construction design.