辐射防护通讯 ›› 2025, Vol. 45 ›› Issue (4): 21-26.

• 研究通报 • 上一篇    下一篇

某医院儿童CT受检者剂量调查与分析

岳磊, 闫庆倩, 杨声, 齐婕   

  1. 南京市疾病预防控制中心,南京 210003
  • 收稿日期:2024-12-31 出版日期:2025-08-20 发布日期:2026-01-15
  • 作者简介:岳磊(1993—),男,2018年毕业于皖南医学院预防医学专业 ,获医学学士学位,主管医师,从事放射卫生检测与评价工作。E-mail:njcdcyl@163.com

Investigation and analysis of radiation dose for pediatric CT examinees in a hospitals

YUE Lei, YAN Qingqian, YANG Sheng, QI Jie   

  1. Nanjing Municipal Center for Disease Control and Prevention, Nanjing 210003
  • Received:2024-12-31 Online:2025-08-20 Published:2026-01-15

摘要: 通过调查南京市某医院儿童CT扫描辐射剂量分布,评估该医院CT检查中儿童受检者的辐射剂量水平,并为探讨建立该医院儿童CT检查诊断参考水平(DRL)提供依据。回顾性收集2020年至2024年期间在该医院进行CT检查的儿童受检者基本信息和CT检查影像学资料,分别收集头颅、胸部和腹部3个检查部位,将受检者按照<1、1~<5、5~<10、10~≤15岁分为4个年龄组,分析同一部位不同年龄组之间的剂量分布差异;并将容积CT剂量指数(CTDIvol)和剂量长度乘积(DLP)的P50位数作为典型值,与其他地区进行比较。<1、1~<5、5~<10、10~≤15岁组各检查部位CTDIvolDLPP50位数分别为,头颅:4.3、6.9、7.4、8.2 mGy和78.9、143.3、153.5、173.0 mGy·cm;胸部:1.7、2.1、3.4、4.1 mGy和32.9、50.9、90.2、131.7 mGy·cm;腹部:2.2、3.8、4.2、5.7 mGy和55.8、137.5、175.0、290.1 mGy·cm。同一部位不同年龄组之间CTDIvolDLP差异有统计学意义(头颅、胸部和腹部,CTDIvol:χ2=173.47、199.91、158.91,DLP:χ2=186.73、265.97、210.99,P<0.001)。该医院儿童受检者各部位的CTDIvolDLPP50位数普遍低于全国水平,但依然存在部分受检者CTDIvolDLP高于GBZ 130—2020标准引用的DRL,因此有必要进一步优化CT扫描程序。

关键词: 儿童, CT, 辐射剂量, 诊断参考水平

Abstract: This study investigated the radiation dose distribution of children′s CT scans in a hospital in Nanjing, with the aim of understanding the radiation dose levels of pediatric subjects in the hospital′s CT examinations and providing a basis for exploring and establishing the diagnostic reference level (DRL) for children′s CT examinations in this hospital. This study retrospectively collected basic information and CT imaging data of pediatric subjects who underwent CT diagnosis at the hospital from 2020 to 2024. Three examination sites, namely the head, chest, and abdomen, were collected, and the subjects were divided into four age groups according to age<1, 1~<5, 5~<10, and 10~≤ 15 years old. The differences in dose distribution between different age groups in the same site were analyzed; At the same time, this article used the median(P50) of CTDIvol and DLP as dose reference levels to compare with other regions. The median values(P50) of CTDIvol and DLP at the corresponding examination sites in the four age groups of<1~<5, 5~<10, 10~≤ 15 years old were as follows: head: 4.3, 6.9, 7.4, 8.2 mGy and 78.9, 143.3, 153.5, 173.0 mGy·cm; Chest: 1.7, 2.1, 3.4, 4.1 mGy and 32.9, 50.9, 90.2, 131.7 mGy·cm; Abdomen: 2.2, 3.8, 4.2, 5.7 mGy and 55.8, 137.5, 175.0, 290.1 mGy·cm. Among them, there were statistically significant differences in CTDIvol and DLP between different age groups of the same body part (head, chest, and abdomen, CTDIvol:χ2=173.47,199.91,158.91; DLP:χ2=186.73,265.97,210.99,P<0.001). The P50 digits of CTDIvol and DLP in various body parts of pediatric patients in this hospital are generally lower than the national level, However, there are still some examinees whose CTDIvol and DLP are higher than DRL cited in GBZ 130—2020. Therefore, it is necessary to further optimize the CT scanning program.

Key words: children, CT, radiation dose, diagnostic reference level

中图分类号: 

  • R144.1